Performance
:
Acoustics
Acoustical options available.:
Sound Absorption (NRC)
A measure for rating the overall sound absorption of a material when used in an enclosed architectural space where sound is reflected at many angles of incidence. A ceiling system with an NRC < 0.50 is low performance, an NRC > 0.70 is high performance.: 0.70
Sound Blocking (CAC)
A measure for rating the performance of a ceiling system as a barrier to airborne sound transmission through a common plenum between adjacent closed spaces. A ceiling system with a CAC < 25 is considered low performance, whereas one with CAC of 35 or higher is high performance.: 35
:
Fire:
Fire Performance: Fire Resistive
Fire Resistance *
Fire Guard/Fire Resistive products tested in specific UL floor/ceiling or roof/ceiling design assemblies.: FireGuard
Light Reflectance
Light reflectance average of 0.83 or greater. White only.: 85%
Sag/Humidity Resistance
Ceiling panels maintain humidity and sag resistance.: HumiGuard Plus
Insulation Value: R Factor-BTU: 1.5 BTU
R Factor-Watts: 0.26 m2 K/W
BioBlock
Ceilings with BioBlock performance resist the growth of mold and mildew.: Yes
Physical Data
Material: Mineral Fiber
Texture: Medium
Surface Finish: Factory applied latex paint
Shape: Rectangle
Sq Ft (Sq Ft / Carton): 64
Pieces / Carton: 8
ASTM Classification: Type: III, Form: 2, Pattern: C E